lower than the “Switch On temperature” to prevent the fan from
switching in and out repeatedly.
11.6 Electric Intercooler Fan Control (IF)
This function can be used to switch an intercooler fan on when the intake-air temperature
exceeds a certain value. The fan will stay on until the engine temperature drops sufficiently.
Switch On Temp. 0 – 127 °C / 32 - 261 °F
The temperature the intake-air must exceed to switch the fan on.
Switch Off Temp. 0 – 127 °C / 32 - 261 °F
The temperature below which the intake-air must drop before
the fan will be switched off. This parameter should be around
3- lower than the Switch On temp.” to prevent the fan from
switching in and out repeatedly.