CHAPTER 11 DIGITAL OUTPUTS & PWM OUTPUTS
The digital outputs and PWM outputs can be programmed to operate a wide variety of
functions. Some of the functions have restrictions to their operation.
Below is a table showing the ECU’s configurable outputs and their factory information.
Output Information
ECU Output
Factory feature Pin
Digital Out 1 TCC A7
Digital Out 2 Thermo fan C1
PWM Out 1 A/C Control C2
PWM Out 2 4
th
Gear C7
PWM Out 3 Spare F2
PWM Out 4 Spare F4
Auxiliary Out (Aux Out) Bypass D5
The functions and their restrictions are described in the table below:
Output Description Digital Out 1–2 PWM 1 – 4 Max #
Turbo Wastegate N/A
•
2
Bypass Air Control (BAC) N/A
•
1
Dual Intake Valve
• •
Unrestricted
Torque Converter Control
• •
1
Thermofan
• •
Unrestricted
Intercooler Fan
• •
Unrestricted
Shift Light
• •
Unrestricted
Aux Fuel Pump
• •
Unrestricted
Stall Saver
• •
1
Staging Signal
• •
Unrestricted
Turbo Timer
• •
1
NOS Switch
• •
1
Anti-Lag Switch
• •
1
BAC2 N/A PWM 3 & 4 1
BAC2/BAC Slave N/A PWM 3 & 4 1
TPS Switch
• •
Unrestricted
For installation information regarding any hardware associated with the described output
functions refer to CHAPTER 1 Haltech ECU Installation, p11.
Each individual function and its parameters are described below.